SR-22DC-DA-R-B

Nano PLC, Ethernet PLC
Power supply: DC 12-24V/AC 24V
Input: 6 DI/AI(0-10V) + 8 DI
Output: 8 Relay
Ethernet
Modbus RTU/ASCII, Modbus TCP
High Quality
CE Certified
Fast Delivery
OEM/ODM
Global Export
Professional Service

SR-22DC-DA-R-B is a 22-point smart relay with mixed digital/analog inputs, 8 relay outputs and built-in Ethernet — more points and analog input flexibility in one DIN-rail unit.

GENERAL SPECIFICATIONS

Timers : 512

Counters: 512

Function Blocks: 512

Operation temp.: -20℃~+55℃

Storage: -40℃~+70℃

Protection: IP20(Non-waterproof)

RTC accuracy: MAX ±2S/day

RTC Backup at 25 °C: 20 days

Program and settings Backup:10 years

Data Power-off retentivity: 10 years

Dimensions : 133*90*60 (Unit, mm)

Certificate   : CE

Installation  : 35mm-DIN rail or screw for installation

Modify parameters via keypad LCD: No

Supported programming language: FBD & Ladder

Expansion capacity: 3 modules (SR-E)

Password protection: 4-digit number password protection or disable program upload function

Communication interface:  2 RS485 port (COM1 external - SR-RS485, COM2 built-in), 1Ethernet port(10M)

Communication protocol: Modbus RTU, Modbus TCP

Technical Index

Power supply:

Nominal voltage

DC12-24V /AC24V

Operating limits

DC10.8-28.8V

AC 21.6-26.4V

Immunity from micro power cuts

Typ.5 ms

Max. Startup current

Max. 0.4A

Max. absorbed power

0.32A (10.8V dc); 0.12A (28.8V dc)

0.28A (24V ac)

Protection against polarity inversions

Yes

Input parameters:

Input No

14 (I1-IE)

Digital input

14 (I1-IE)

Analogue input

6 (I1-I6) (0...10V DC)

Digital inputs (I7-IE)

Input voltage

DC 0-28.8V

AC 0-24V

Input signal0

< 5V DC; <1 mA

< 3V AC

Input signal1

> 8V DC; >1.7 mA

> 6V AC

Input current

2.1mA @ 10.8V dc

2.3mA @ 12.0 V dc

4.6 mA @ 24 V dc

5.5 mA @ 28.8 V dc

4.76 mA @ 24 V ac

Response time

DC12-24V

0 to 1:  Typ. 3ms;

1 to 0:  Typ. 3ms

AC24V

0 to 1:  Typ. 72ms;

1 to 0:  Typ. 72ms

Maximum counting frequency

65k Hz(I9—IC)

Sensor type

Contact or 3-wire PNP

Input type

Resistive

Isolation between power supply and inputs

None

Isolation between inputs

None

Inputs used as digital inputs (I1-I6)

Input voltage

DC 0-28.8V

AC 0-24V

Input signal0

< 5V DC; <0.09 mA

< 3V AC

Input signal1

> 8V DC; >0.15mA

> 5V AC

Input current

0.16mA @ 10.8V dc

0.18mA @ 12.0 V dc

0.49mA @ 24 V dc

0.62mA @ 28.8 V dc

0.58 mA @ 24 V ac

Response time

DC12-24V

0 to 1: Typ. 5 ms;

1 to 0: Typ. 5 ms

AC24V

0 to 1:Typ. 40ms

1 to 0:Typ. 40ms

Maximum counting frequency

Typ.:4 HZ

Sensor type

Contact or 3-wire PNP

Input type

Resistive

Isolation between power supply and inputs

None

Isolation between inputs

None

Inputs used as analog inputs (I1-I6)

Measurement range

DC 0---10V

Input impedance

Min, 24KΩ; Max. 72KΩ

Input voltage

28.8 V DC max

Resolution

10bit ,0.01V

Accuracy at 25 °C

± (Max.0.2)V

Isolation between analog channel and power supply

None

Cable length

10 m max.  shielded and twisted

Output parameters:

Output No.

8 (Q1-Q8)

Output type

Relay output

Safety certified load (resistive)

10A,250V AC

Min switching load

6V 1A

Electrical endurance (360ops/h)

10 5 (at room temperature)

Mechanical endurance 10,800ops/h

10 7 (at room temperature)

Response time

Operate Time: 15 mSec. Max.

Release Time: 10 mSec. Max.

Built-in protections

Against short-circuits: None

Against over-voltages and overloads: None

Switch frequency:

Mechanism

10Hz

Resistor/light load

2Hz

Sensitive load

0.5Hz

LED Indicator Status:

ETH

(Ethernet Communication Indicator)

ETH_LINK: Green (indicates the network connection is established.)

ETH_DATA: Flashing yellow (indicates communication data is being transmitted.)

RUN/STOP

(PLC Run/Stop Indicator)

Green: RUN status

Red: STOP status

Other parameters:

Weight

250g

Installation Dimensions & Wiring Diagram

Download product datasheet