SR-22AC-R-B
Power supply: AC 110V-240V
Input: 14 DI(AC)
Output: 8 Relay
Ethernet
Modbus RTU/ASCII, Modbus TCP
SR-22AC-R-B is a 22-point smart relay with 14 AC inputs, 8 relay outputs and built-in Ethernet — high I/O smart-relay control for AC-powered machines.
GENERAL SPECIFICATIONS
Timers : 512
Counters: 512
Function Blocks: 512
Operation temp.: -20℃~+55℃
Storage : -40℃~+70℃
Protection: IP20 (Non-waterproof)
RTC accuracy: MAX ±2S/day
RTC Backup at 25 °C: 20 days
Program and settings Backup:10 years
Data Power-off retentivity: 10 years
Dimensions : 133*90*60 (Unit, mm)
Certificate : CE
Installation : 35mm-DIN rail or screw for installation
Modify parameters via keypad LCD: No
Supported programming language: FBD & Ladder
Expansion capacity: 3 modules (SR-E)
Password protection: 4-digit number password protection or disable program upload function
Communication interface: 2 RS485 port (COM1 external - SR-RS485, COM2 built-in), 1 Ethernet port(10M)
Communication protocol: Modbus RTU, Modbus TCP
|
Technical Index |
||
|
Power supply: |
||
|
Nominal voltage |
AC110V-240V |
|
|
Operating limits |
AC85-265 V |
|
|
The main frequency range |
47-63Hz |
|
|
Max. absorbed power |
80mA (85V ac); 40mA (265V ac) |
|
|
Surge Immunity |
1780V AC |
|
|
Protection against polarity inversions |
Yes |
|
|
Input parameters: |
||
|
Input No |
14 (I1-IE) |
|
|
Digital input |
14 (I1-IE) |
|
|
Analogue input |
None |
|
|
Input voltage |
AC110-240V |
|
|
Input signal0 |
AC0-40V; <0.03mA |
|
|
Input signal1 |
AC79-240V; >0.06mA |
|
|
Input Response Time |
Delay time at 0 to 1: 120V AC: Typ. 30 ms 240V AC: Typ. 20 ms Delay time at 1 to 0: 120V AC: Typ. 130 ms 240V AC: Typ. 120 ms |
|
|
Maximum counting frequency |
Typ. 2Hz |
|
|
Sensor type |
Contact or 3-wire PNP |
|
|
Isolation between power supply and inputs |
None |
|
|
Isolation between inputs |
None |
|
|
Protection against polarity inversions |
Yes |
|
|
Output parameters: |
||
|
Output No. |
8 (Q1-Q8) |
|
|
Output type |
Relay output |
|
|
Safety certified load (resistive) |
8A,277V AC |
|
|
Min switching load |
6V 1A |
|
|
Electrical endurance (360ops/h) |
10 5 (at room temperature) |
|
|
Mechanical endurance 10,800ops/h |
10 7 (at room temperature) |
|
|
Response time |
Operate Time: 15 mSec. Max. Release Time: 10 mSec. Max. |
|
|
Built-in protections |
Against short-circuits: None Against over-voltages and overloads: None |
|
|
Switch frequency: |
||
|
Mechanism |
10Hz |
|
|
Resistor/light load |
2Hz |
|
|
Sensitive load |
0.5Hz |
|
|
LED Indicator Status: |
||
|
ETH (Ethernet Communication Indicator) |
ETH_LINK: Green (indicates the network connection is established.) |
|
|
ETH_DATA: Flashing yellow (indicates communication data is being transmitted.) |
||
|
RUN/STOP (PLC Run/Stop Indicator) |
Green: RUN status Red: STOP status |
|
|
Other parameters: |
||
|
Weight |
250g |
|
Installation Dimensions & Wiring Diagram