SR-22AC-R-B

Nano PLC, Ethernet PLC
Power supply: AC 110V-240V
Input: 14 DI(AC)
Output: 8 Relay
Ethernet
Modbus RTU/ASCII, Modbus TCP
High Quality
CE Certified
Fast Delivery
OEM/ODM
Global Export
Professional Service

SR-22AC-R-B is a 22-point smart relay with 14 AC inputs, 8 relay outputs and built-in Ethernet — high I/O smart-relay control for AC-powered machines.

GENERAL SPECIFICATIONS

Timers : 512

Counters: 512

Function Blocks: 512

Operation temp.: -20℃~+55℃

Storage : -40℃~+70℃

Protection: IP20 (Non-waterproof)

RTC accuracy: MAX ±2S/day

RTC Backup at 25 °C: 20 days

Program and settings Backup:10 years

Data Power-off retentivity: 10 years

Dimensions : 133*90*60 (Unit, mm)

Certificate   : CE

Installation  : 35mm-DIN rail or screw for installation

Modify parameters via keypad LCD: No

Supported programming language: FBD & Ladder

Expansion capacity: 3 modules (SR-E)

Password protection: 4-digit number password protection or disable program upload function

Communication interface:  2 RS485 port (COM1 external - SR-RS485, COM2 built-in), 1 Ethernet port(10M)

Communication protocol: Modbus RTU, Modbus TCP

Technical Index

Power supply:

Nominal voltage

AC110V-240V

Operating limits

AC85-265 V

The main frequency range

47-63Hz

Max. absorbed power

80mA (85V ac); 40mA (265V ac)

Surge Immunity

1780V AC

Protection against polarity inversions

Yes

Input parameters:

Input No

14 (I1-IE)

Digital input

14 (I1-IE)

Analogue input

None

Input voltage

AC110-240V

Input signal0

AC0-40V; <0.03mA

Input signal1

AC79-240V; >0.06mA

Input Response Time

Delay time at 0 to 1:

120V AC:  Typ. 30 ms

240V AC:  Typ. 20 ms

Delay time at 1 to 0:

120V AC:  Typ. 130 ms

240V AC:  Typ. 120 ms

Maximum counting frequency

Typ. 2Hz

Sensor type

Contact or 3-wire PNP

Isolation between power supply and inputs

None

Isolation between inputs

None

Protection against polarity inversions

Yes

Output parameters:

Output No.

8 (Q1-Q8)

Output type

Relay output

Safety certified load (resistive)

8A,277V AC

Min switching load

6V 1A

Electrical endurance (360ops/h)

10 5 (at room temperature)

Mechanical endurance 10,800ops/h

10 7 (at room temperature)

Response time

Operate Time: 15 mSec. Max.

Release Time: 10 mSec. Max.

Built-in protections

Against short-circuits: None

Against over-voltages and overloads: None

Switch frequency:

Mechanism

10Hz

Resistor/light load

2Hz

Sensitive load

0.5Hz

LED Indicator Status:

ETH

(Ethernet Communication Indicator)

ETH_LINK: Green (indicates the network connection is established.)

ETH_DATA: Flashing yellow (indicates communication data is being transmitted.)

RUN/STOP

(PLC Run/Stop Indicator)

Green: RUN status

Red: STOP status

Other parameters:

Weight

250g

Installation Dimensions & Wiring Diagram

Download product datasheet