PR-E-16DC-DA-R

Expansion module
Power supply: DC 12-24V
Input: 4 DI/AI(0-10V) + 4 DI
Output: 8 Relay
High Quality
CE Certified
Fast Delivery
OEM/ODM
Global Export
Professional Service

PR-E-16DC-DA-R is an expansion module for PR CPUs adding 4 mixed AI/DI channels, 4 digital inputs and 8 relay outputs — analog plus relay expansion in one unit.

Specifications

Technical Index

Power supply:

Nominal voltage

DC 12-24V

Operating limits

DC 10.8-28.8V

Immunity from micro power cuts

Typ.5 ms

Max. Startup current

Max. 0.4A

Max. absorbed power

3.5W (10.8V dc); 4.5W (28.8V dc)

Protection against polarity inversions

Yes

Input parameters:

Input No

8 (I1-I8)

Digital input

8 (I1-I8)

Analogue input

4 (I1-I4) (0...10V DC)

Digital inputs (I5-I8)

Input voltage

DC0-28.8V

Input signal 0

< 5V DC; <1mA

Input signal 1

> 8 V DC; >1.7mA

Input current

2.3mA @ 10.8V dc
2.6mA @ 12.0 V dc
5.2 mA @ 24 V dc
6.3 mA @ 28.8 V dc

Response time

0 to 1: <1 ms; 1 to 0: <1 ms

Maximum counting frequency

4 Hz(I5--I8)

Sensor type

Contact or 3-wire PNP

Input type

Resistive

Isolation between power supply and inputs

None

Isolation between inputs

None

Inputs used as digital inputs (I1-I4)

Input voltage

DC0-28.8V

Input signal0

< 5V DC;<0.1mA

Input signal1

> 8 V DC;>0.3mA

Input current

0.4mA @ 10.8V dc

0.5mA @ 12.0 V dc

1.2mA @ 24 V dc

1.5mA @ 28.8 V dc

Response time

0 to 1: Typ. 1.5 ms ; 1 to 0 : Typ. 1.5 ms

Maximum counting frequency

Typ.:4 HZ

Sensor type

Contact or 3-wire PNP

Input type

Resistive

Isolation between power supply and inputs

None

Isolation between inputs

None

Inputs used as analog inputs (I1-I4)

Measurement range

DC 0---10V

Input impedance

Min, 24KΩ; Max. 72KΩ

Input voltage

28.8 V DC max

Resolution

9bit ,0.015V

Accuracy at 25 °C

± (Max.0.2)V

Isolation between analog channel and power supply

None

Cable length

10 m max.  shielded and twisted

Output parameters:

Output No.

8 (Q1-Q8)

Output type

Relay output

Safety certified load (resistive)

(Q1-Q4) 3A 250VAC

(Q5-Q8) 10A 250V AC

Min switching load

6V 1A

Electrical durability Expectancy

10 5 Operations at Rated Resistive Load

Mechanical life

10 7 Operations at No Load condition

Response time

Operate Time: 15 mSec. Max.

Release Time: 10 mSec. Max.

Built-in protections

Against short-circuits: None

Against over-voltages and overloads: None

Switch frequency:

Mechanism

10Hz

Resistor/light load

2Hz

Sensitive load

0.5Hz

Other parameters:

Operation temp

-20℃-+55℃

Storage temp

-40℃-+70℃

Address Setting for Expansion Modules

When multiple expansion modules are connected to one single CPU PLC, each expansion module must be assigned a distinct station address.

Factory default expansion address: 1. The expansion address is configured via DIP switch. The corresponding relationship between expansion address number and DIP switch status is shown below:

Installation Dimensions & Wiring Diagram

Download product datasheet