PR-12AC-R-N

Ethernet PLC
Power supply: AC 110V-240V
Input: 8 DI(AC)
Output: 4 Relay
Ethernet, 1 built-in RS485
Modbus RTU/ASCII, Modbus TCP, MQTT, BACnet MSTP / BACnet IP
High Quality
CE Certified
Fast Delivery
OEM/ODM
Global Export
Professional Service

PR-12AC-R-N is a 12-point Ethernet Micro PLC with 8 AC inputs, 4 relay outputs and native Modbus TCP, MQTT and BACnet over wired Ethernet — a connected core for small machines that must report to SCADA, BMS or the cloud.

GENERAL SPECIFICATIONS

Timers: 512

Counters: 512

Function Blocks: 512

Operation temp.: -20°C - +55°C

Storage: -40°C - +70°C

Protection: IP20 (Non-waterproof)

RTC accuracy  : MAX ±2S/day

RTC Backup at 25 °C: 20 days

Program and settings Backup: 10 years

Data Power-off retentivity: 10 years

Modify parameters via keypad LCD: YES

Dimensions: 95*90*61(Unit:mm)

Certificate: CE

Installation: 35-DIN rail or screw for installation

Supported programming language: FBD & Ladder

Expansion capacity: 16 modules (PR-E-16)

Password protection: 4-digit number password protection or disable program upload function

Communication interface: 1 RS232 Port (COM0 – RS232 Cable), 2 RS485 port (COM1 available via SR-RS485, C0M2 - built-in RS485 port), 1 Ethernet port.

Communication protocol: Modbus RTU/ASCII, Modbus TCP, MQTT, BACnet

Technical Index

Power supply:

Nominal voltage

AC110V-240V

Operating limits

AC85 - 265 V

The main frequency range

47-63Hz

Max. absorbed power

50mA (85V ac); 40mA (265V ac)

Surge Immunity

1780V AC

Protection against polarity inversions

Yes

Input parameters:

Input No

8

Digital input

8 (I1-I8)

Analogue input

None

Input voltage

AC110-240V

Input signal0

AC0-40V;<0.015mA

Input signal1

AC79-240V;>0.06mA

Input Response Time

Delay time at 0 to 1:

120V AC :Typ. 50 ms

240V AC :Typ. 30 ms

Delay time at 1 to 0:

120V AC :Typ. 100 ms

240V AC :Typ.130 ms

Maximum counting frequency

Typ. 4Hz

Sensor type

Contact

Isolation between power supply and inputs

None

Isolation between inputs

None

Protection against polarity inversions

Yes

Output parameters:

Output No.

4 (Q1-Q4)

Output type

Relay output

Safety certified load (resistive)

10A 250V AC

Min switching load

6V 1A

Electrical durability Expectancy

10 5 Operations at Rated Resistive Load

Mechanical life

10 7 Operations at No Load condition

Response time

Operate Time: 15 mSec. Max.

Release Time: 10 mSec. Max.

Built-in protections

Against short-circuits: None

Against over-voltages and overloads: None

Switch frequency:

Resistor/light load

2Hz

Sensitive load

0.5Hz

Other parameters:

Weight

Approx.400g

Installation Dimensions & Wiring Diagram

Download product datasheet